Image

PRECAST & PRESTRESSED CONCRETE

Product overview

Square piles are produced in 12”, 20” and 24” sections. The P-12S pile has a circular strand pattern and spiral. The P-20S & P-24S pile have square strand patterns. A square spiral should be used in lieu of individual ties for this product.

Categories
Explore specifications ↓

Key specifications

Square Pile - section summary
SectionNominal sizeSection properties
P12S12 in square144 in² area / 155 lb per linear ft
P20S20 in square400 in² area / 431 lb per linear ft
P24S24 in square576 in² area / 620 lb per linear ft

Design & detailing notes

  • P12S uses a circular strand pattern and spiral. P20S and P24S use square strand patterns with spiral reinforcing per design requirements.
  • For P20S and P24S, standard cover to spiral is 3 in; the sheets describe a possible reduction to 2 in for non-marine applications where appropriate for reinforcing requirements.
  • The P12S sheet specifies 2 in cover and notes that this section is generally not recommended for marine applications.
  • Potential strand locations are illustrated; final strand counts depend on design prestressing demand. Slight side draft may be used for stripping.
  • The same PDF also includes P20F and P24F fender-pile insert details.
Source drawings
  • 2-23-10 SQUARE PILE.pdf: P12S, P20S, P24S, P20F, P24F

This summary supports preliminary product selection. Refer to the complete source drawings and coordinate final dimensions, loads and reinforcing with GPRM and the project engineer. The supplied sheets do not show an issued or revised date.